A commercial kitchen hood in New York City is not just a metal canopy over the cooking line. It is a regulated system made up of the hood, the exhaust fan, grease duct, fire suppression and makeup air, and each part has to work together to pass inspection. Restaurant owners who understand how those pieces fit before they sign a contract avoid the most common delays, failed inspections and change orders.

What Is Included in a Commercial Kitchen Hood System

When a contractor quotes a hood installation, the price should cover the whole exhaust path, not only the canopy. Our commercial kitchen hood service covers each of these components as one scope.

  • The hood: sized to the cooking equipment beneath it, with grease filters or baffles and an integrated light fixture.
  • The exhaust fan: usually rooftop mounted, sized to the airflow the hood requires.
  • Grease duct: welded or listed duct that carries grease-laden air out of the building with the clearances and access panels the code requires.
  • Fire suppression: a wet chemical system tied to the hood and to the fuel or power shutoff for the cooking line.
  • Makeup air: a unit that replaces the air the hood removes, so the kitchen does not run under negative pressure. See our guide to kitchen ventilation and makeup air maintenance.

Type I vs Type II Hoods

The first decision is the hood type, and it is set by what the equipment produces, not by preference.

Hood TypeUsed OverKey Requirement
Type IFryers, grills, griddles, ranges, charbroilers and other equipment that produces grease-laden vaporGrease duct, fire suppression and compliance with NFPA 96
Type IIDishwashers, steamers and ovens that produce heat, steam or odor without greaseLighter construction, no grease duct, designed to remove heat and moisture

Many kitchens need both. A pizzeria, for example, may run a Type I hood over a deck oven line and a Type II hood over the dish room. Getting this wrong at design stage is one of the most expensive mistakes in a buildout.

NYC Code and Permit Requirements

New York City layers several requirements on top of the national standard. Your contractor should be able to walk you through each of them before work starts.

  • NFPA 96: the national standard for ventilation control and fire protection of commercial cooking operations, which the NYC Fire Code references for hood and duct systems.
  • Department of Buildings filings: kitchen exhaust is mechanical work, so it generally requires a permit, and new or modified systems may need drawings prepared by a licensed professional.
  • Fire suppression: the suppression system has to be installed by a qualified contractor and tested as part of sign-off.
  • Health Department expectations: inspectors look for clean, functioning ventilation and expect records that show the system is maintained.

Requirements vary by building, lease and the type of cooking, so confirm the filing path for your specific space before you order equipment. Your contractor should also coordinate with your landlord on roof access and duct routing, which is a frequent source of delay.

What Drives the Cost of a Kitchen Hood Installation

There is no honest flat price for a hood, because the cost depends on the building as much as the equipment. These are the factors that move a quote the most.

  • Hood size and type: a longer hood over heavier cooking equipment costs more than a short Type II canopy.
  • Duct run: the distance and number of floors the grease duct has to travel to reach the roof, and any shaft or wall penetrations along the way.
  • Roof work: fan placement, curb work, structural review and any crane or rigging needed.
  • Makeup air: whether the kitchen needs a new unit or can use an existing one.
  • Permits and drawings: filing scope and professional drawings when required.
  • Schedule: overnight or closed-day work to keep the restaurant open.

The best way to compare quotes is to ask each contractor to list the hood, fan, duct, suppression, makeup air and permit work as separate lines, so you are comparing the same scope.

Keeping an Installed Hood Compliant

Installation is the start of the obligation. Grease buildup in the hood and duct is a fire risk, and the cleaning schedule under NFPA 96 depends on how much and what kind of cooking the kitchen does. Higher-volume operations such as charbroiling or 24-hour cooking are cleaned more often than low-volume kitchens. Keep written records of every cleaning and service visit, because inspectors may ask for them. A planned maintenance contract keeps the exhaust, fan and makeup air serviced on a schedule instead of after a failure. For the broader picture of how a restaurant kitchen fits into building mechanical systems, see our restaurant HVAC page.

Planning a Kitchen Hood Install or Replacement?

Send us the address, cooking equipment list and your timeline. We will outline scope, permits and schedule.

Request a Kitchen Hood Quote →
Frequently Asked Questions
What is the difference between a Type I and Type II hood?

A Type I hood is used over equipment that produces grease-laden vapor and requires grease duct and fire suppression. A Type II hood is used over equipment that produces heat, steam or odor without grease, such as dishwashers and some ovens.

Do I need a permit to install a commercial kitchen hood in NYC?

Kitchen exhaust is mechanical work and generally requires Department of Buildings filings, and new or modified systems may require drawings from a licensed professional. Confirm the exact filing path for your space with your contractor before work begins.

Does a new hood require makeup air?

Yes. A hood removes a large volume of air from the kitchen, and that air has to be replaced. Without balanced makeup air the hood underperforms, doors become hard to open, and cooking equipment can run poorly.

Can the work be done without closing my restaurant?

In many cases yes. Installation is commonly scheduled overnight or on closed days so service is not interrupted. Your contractor should confirm the schedule in writing before work starts.

How often does a kitchen hood and duct need cleaning?

The schedule under NFPA 96 depends on the cooking volume and fuel type. Higher-volume cooking is cleaned more often than low-volume cooking, and every cleaning should be documented.